QUICK START GUIDE .
Turn Power on in area of
fresh air and allow to
countdown
Rotate test selector to Fuel.
Press
sUP or tDOWN
to scroll and select desired
fuel. Top line is selected fuel.
Rotate test selector to
“Flue T
est” and begin test
-
ing.
GETTING STARTED
WORKLIGHT AND DISPLAY
BASIC CO/COMBUSTION ANALYSIS
Press and Hold the sUP
button to toggle between
fuel test screens 1 and 2.
Flue Test Pg.1: O2, CO, Draft
(P) and TF
.
Flue T
est Pg. 2: CO2, NO,
Efficiency and Excess Air.
(NO
1
upg
r
ade available on
Eag
le 2 and 2X.
NO
1
comes standard on
Eagle 3 and 3X.)
Make any adjustments as
needed for pr
oper
combustion and wait for
analyzer to display any
change in the readings.
(repeat if necessary)
Once complete, remove
pr
obe from the stack and
allow the analyzer to purge
in fresh air until CO sensor
readings return to ZERO
and O2 reads 20~21%
(20.9%). Continue to the
ne
xt test or turn off your
analyzer if finished.
NOTE: print and store func-
tions may be used at an
y
point during testing
.
Connect flue probe
thermocouple connector to T1,
and connect flue probe to
water trap as shown above.
Use optional probe with T2 for
inlet temperature.
Insert Flue Probe in stack.
A
djust the cone so the end
of the probe is approximate-
ly. at the center of the stack
(4” stack adjust cone to
aprox 2” from end of
probe.)
GAS ZERO (EAGLEX SERIES ONLY)
Rotate test selector to Menu.
Make sure Analyzer is in
fresh air and press ENTER.
Analyzer will then Zero This
takes 90 seconds.
Press
sUP Button to
GAS ZERO and press ENTER.
Re-Zero the analyzer in fresh air if needed for different fuel type or after large temperature rise.
NOTE: The Eagle X will automatically initiate Gas Zero if required for continued accurate results.
Best results are obtained at Steady State Efficiency (SSE). Allow equipment adequate warm-up time prior to testing.
After the Analyzer has
zeroed turn test selector to
a
ppropriate test screen.
P
ress
sU
P at any point to
turn on the backlit display
and worklight.
NOTE: backlight does not
work in the fuel menu.or
during purge.
NOTE: you will have to drill a hole at least 3/8”.
Use a high temp silicone to seal after testing.